Technical Paper
The Influence of a Ceramic Particle Trap on the Size Distribution of Diesel Particles
1985-02-01
850009
The U.S. Bureau of Mines has sponsored research Co determine the particle size distribution and concentration of submicron particles upstream and downstream of a ceramic particle trap mounted in the exhaust stream of a Caterpillar 3304 diesel engine. Particle size distribution and mass were measured with an electrical aerosol analyzer, a diffusion battery-condensation nuclei counter combination, and filters. The engine was operated at 1400 and 1800 RPM and 3 load conditions at each speed-In general, the collection efficiency of the trap was high, ranging between 89 to 96%. Size distribution analysis revealed that the trap was generally more efficient at removing particles smaller than 0.1 µm diameter than larger particles. However, under certain conditions formation of nuclei (less than 0.056 µm diameter) downstream of the trap took place.